Architecture Paint

FIRE KEEPER (MATTE) Flame-resistant water-based white DFW-200F

usage
Inside buildings veneer, medium density fiberboard (MDF), and wood that require a flame retardant function
Flame retardant treatment for veneer and wood in special areas designated by Presidential Decree.

FIRE KEEPER (MATTE) flame-resistant water-based white DFW-200F is a water-based flame-resistant paint designed to be applied on flammable materials such as plywood, wood, MDF, etc. and to exhibit a strong flame-resistant performance even at low film thickness. This product is a special highly functional flame-resistant paint that forms a nonflammable insulation layer when the dry film expands in case of a fire and prevents or delays carbonization of flammable materials such as wood.

specification

Paint type
Special water-based emulsion resin
Drying time
Drying time
Category 5℃ 20℃ 30℃
Dry-through 2 hours 1 hour 40 minutes
Time required for re-coating (min.) 4 hours 2 hours 90 minutes
Thinner
Tap water(dilution rate: up to 25%, volume ratio)
Coating Method
Brush, roller, spray coating.
Specific gravity
Approx. 1.3
Type approval No.
YUM 04-16
Theoretical Coverage
6.0 ㎡/ℓ
Solid volume ratio
50±1 %
Re-coating interval
20℃, sufficient ventilation for a minimum of 2 hours
Thickness of dried film
83㎛ (2~3 coats recommended)
Gloss
Matte
Color
White
Storage and preservation
12 months (well-ventilated dry, cold and dark location, room temperature 5℃~30℃, humidity less than 80%)

PRODUCT PROPERTIES (PHYSICAL PROPERTY DATA)

Flame-resistant performance
As the flame-resistant treatment area is large, flame-resistant performance and workability are excellent.
Environmental impact
It is a water-based product not containing harmful heavy metals and having less content of organic solvents.
Professionalism
Flame-resistant paint is recognized as flame retardant treatment only when applied by a registered fire retardant treatment business among firefighting facilities businesses.

how to use

Surface treatment
1. Completely remove oil, moisture and foreign substances from the surface.
2. For undercoating, use the designated primer, FIRE KEEPER WATER-BASED LACQUER SURFACER or GREEN LACQUER SURFACER if necessary.
Coating method
1. Sufficiently stir before use.
2. When painting brushes or rollers, add coating 100 with a constant water value of 20 or less, when painting spray, add coating 100 at a rate not more than 25 designated thinners, after applying sufficiently stir, paint at least three times.
3. Upon re-coating following the primary coating, apply after completely drying for at least 2 hours at 25℃.
4. The amount of dough (D,F,T) should be 83㎛ (0.083㎜) or more.