Architecture Paint

RAIN COAT(SOLVENT-BASED WATER REPELLENT) DRC-200

usage
All building materials that water can penetrate into such as concrete, cement mortar, plaster, bricks and roof tiles

This product is excellent in water repellency, having good penetration power and good alkali resistance when applied to cement mortar or concrete. Therefore, it fundamentally blocks the penetration of water into the material and prevents damage by freezing or salt, chemical destruction and erosion by organisms. A coating film is not formed on the surface of the material, and a colorless, transparent, and natural appearance is maintained.

specification

Paint type
Silicone compound
Drying time
Drying time
Category 5℃ 20℃ 30℃
Time required for re-coating (min.) 36 hours 24 hours 18 hours
Thinner
Use of undiluted solution
Coating Method
Brush, roller, spray coating
Specific gravity
Approx. 1.0±0.10
Color
Transparent

PRODUCT PROPERTIES (PHYSICAL PROPERTY DATA)

Water repellency
Permeability is superior and water repellency is maintained for a long period of time.
Film performance
It extends the life of buildings by preventing water penetration into the base.

how to use

Surface treatment
1. The material should be sufficiently cured (cured more than 30 days at 20℃)
2. Laitance, dust, oil and other contaminants on the surface must be completely removed.
3. The proper pH of the material must be less than 9, and the percentage of moisture content must be less than 6%.
Coating method
1. Shake well before use and do not dilute upon use.
2. If the surface is wet with water or is moist, coating is impossible. Do not try to coat, but apply after at least 24 hours of drying.
3. Upon coating, apply with a brush, roller, or low-pressure spray device so that it can penetrate into the surfaceas deeply as possible.

Theoretical Coverage

Basis material

Application amount

Cement mortar

0.3~0.4 L/㎡ 

Concrete

0.3~0.5 L/㎡

Brick

0.4~0.5 L/㎡

Light brick

0.5~0.8 L/㎡