Waterproof Coating
SINGLETHANE GOLD(VERTICAL) One-component elastic urethane waterproofing for exposure
- usage
- Waterproof coating exclusive for rooftops and exposed areas
This paint is a one-component elastic urethane intermediate coating that is excellent in physical performance in terms of elongation, adhesion, elasticity and impact resistance. In particular, as a one-component type, it can be used immediately without stirring the base and the hardener and can be applied to vertical surfaces. It is a one-component elastic urethane waterproofing material that is excellent in the elongation and elastic effect of coating. Thick coating is possible even for vertical surfaces due to the viscosity of the paint. It is a paint suitable for the waterproofing of vertical surfaces.
specification
- Paint type
- Polyurethane resin (1-Component)
- Drying time
-
Drying time Category 5℃ 20℃ 30℃ Set-to-touch 12 hours 7 hours 5 hours Dry-through 72 hours 24 hours 18 hours Over-coat (Min.) 3 days 1 days 18 hours Over-coat (Max.) 4 days 3 days 1.5 days Pot life 60 minutes 30 minutes 20 minutes - Thinner
- Not Applicable
- Specific gravity
- Approx. 1.5
- Dilution ratio
- Dilution ratio ▷ No dilution
- Theoretical Coverage
- 5.0 ㎏/㎡ (Based on 3㎜)
- Solid volume ratio
- More than 90 %
- Color
- Green
- Thickness of dried film
- 3 ㎜
- Flash point
- 33 ℃
- Shelf life
- 6 months
- Packaging unit
- 18 ㎏
PRODUCT PROPERTIES (PHYSICAL PROPERTY DATA)
- Tensile strength
- More than 2.5 N/㎟
- Elongation rate
- More than 450 %
- Tearing strength
- More than 14.7 N/㎜
- Hardness
- shore A 60 ± 10
how to use
- Surface treatment
- 1. Cure concrete for at least 28 days at a temperature of 21℃ and a relative humidity of 50%.
2. Completely remove the oil, moisture, sand, dust, laitance and other foreign matter from the surface and maintain surface smoothness.
3. For high-strength concrete (260㎏/㎠ or higher), blasting treatment should be carried out. - Coating method
- 1. Reinforce cracks, crevices, and joints between walls and floors with the NEW-THANSUNG SEAL(N).
2. Apply SINGLETHANE with sawtooth scraper, rubber scraper, pitchfork, etc. by dividing into primary scrapping (0.5~1.0㎜) and secondary main coating. Applying a thick coat (2㎜ or more) at once may cause drying failure.
Appropriate construction specifications
▷Primer : CLEANTHANE 1000
▷Intermediate coating : NEW SINGLETHANE
▷Top coat : CLEANTHANE 3000K - Coating conditions
- 1. Atmosphere Temperature: 5~35℃, Surface Temperature: 40℃ or below, Relative Humidity: 80% or less.
2. Moisture content in the concrete: 6% or less.