Waterproof Coating
WATERBORNE CLEANTHANE TOP COAT Waterborne urethane top coat
- usage
- Waterborne waterproofing top coat
Waterborne Cleanthane Top coat is a two-component waterborne elastic urethane topcoat composed of waterborne urethane resin. It has decent flexbility, water resistance, coverage, adhesion and wear resistance.
specification
- Paint type
- Waterbone polyurethane resin (2-Component)
- Drying time
-
Drying time Category 10℃ 20℃ 30℃ Set-to-touch 1 hour 30 minutes 20 minutes Dry-through 36 hours 18 hours 8 hours Over-coat(Min.) 36 hours 18 hours 8 hours Over-coat(Max.) 5 days 3 days 2 days Pot life 3 hours 2 hours 1 hour - Thinner
- Dilute it with tap water by 15% or less(if necessary)
- Coating Method
- Brush, roller, spray coating
- Specific gravity
- Approx. 1.2 (Gray)
- Theoretical Coverage
- 0.15 ㎏/㎡ (Gray)
- Solid volume ratio
- 45±3% % (Gray)
- Color
- Green, Gray
- Thickness of dried film
- 50 ㎛
- Mixing ratio
- Base(A)/hardener(B)=3.7/1 (Weight ratio)
- Gloss
- Glossy
- Shelf life
- 12 months (Room temperature 5℃~30℃)
- Packaging unit
- 15 ㎏ [Base(11.8㎏), Hardener(3.2㎏)]
how to use
- Surface treatment
- 1. Cure concrete for at least 28 days at a temperature of 21℃ and a relative humidity of 50%.
2. Completely remove the oil, moisture, sand, dust, laitance and other foreign matter from the surface and maintain surface smoothness.
3. For high-strength concrete (260㎏/㎠ or higher), blasting treatment should be carried out. - Coating method
- 1. Reinforce cracks, crevices, and joints between walls and floors with an elastic putty.
2. Mix Part A and Part B with a power disperser. Dilute them with tap water and mix thoroughly.
3. Apply smoothly on the undercoated/intermediate coated surface using brush, roller, sray, etc.
Appropriate construction specifications
▷Primer : WATERBONE CLEANTHANE PRIMER
▷Intermediate coating : WATERBONE CLEANTHANE INTERMEDIATE COATING
▷Top coat : WATERBONE CLEANTHANE TOP COAT - Coating conditions
- 1. Atmosphere Temperature: 10~35℃, Surface Temperature: 40℃ or below, Relative Humidity: 80% or less
Above pot life and follow-up coating time have been measured under laboratory conditions and may vary depending on the construction site.