Waterproof Coating

ENERGY SAVER Urethane(R) top coat

usage
Exposure type waterproofing material top coat

This paint is a heat shield waterproofing top coat manufactured by using non-yellowing 2K elastic urethane resin and special ceramic material. It reflects infrared rays during painting and shows a heat shielding effect by preventing the heat of the surface from being transmitted to the inside. Unlike ordinary urethane paints, it is highly flexible and suitable as a top material for waterproofing materials. In particular, it is excellent in hiding power, adhesion and abrasion resistance, and it is an exposed type heat shielding top coat for waterproofing materials.

specification

Paint type
Polyurethane resin (2-Component)
Drying time
Drying time
Category 5℃ 20℃ 30℃
Set-to-touch 1 hour 30 minutes 20 minutes
Dry-through 18 hours 12 hours 8 hours
Over-coat (Min.) 18 hours 12 hours 8 hours
Over-coat (Max.) 5 days 3 days 2 days
Pot life 6 hours 4 hours 2 hours
Thinner
DR-700, DR-700L
Specific gravity
1.10±0.05 (Based on white color)
Dilution ratio
▷ Dilution rate: up to 10%, volume ratio
Theoretical Coverage
0.11 ㎏/㎡
Solid volume ratio
43±3 % (Based on green color)
Color
White, bright gray, gray, green
Thickness of dried film
40 ㎛
Mixing ratio
Base(A)/Hardener(B)=8/1 (Weight ratio)
Gloss
Glossy
Shelf life
12 months
Packaging unit
16L
Flash point
27 ℃

PRODUCT PROPERTIES (PHYSICAL PROPERTY DATA)

Certification Status
U.S. Cool Roof Rating Council Certification, U.S ENERGY STAR Certification: white, bright gray, gray, bright green, green

how to use

Surface treatment
1. Cure concrete for at least 28 days at a temperature of 21℃ and a relative humidity of 50%.
2. Completely remove the oil, moisture, sand, dust, laitance and other foreign matter from the surface and maintain surface smoothness.
3. For high-strength concrete (260㎏/㎠ or higher), blasting treatment should be carried out.
Coating method
1. Reinforce cracks, crevices, and joints between walls and floors with the NEW-THANSUNG SEAL(N).
2. Apply smoothly on the undercoated surface using sawtooth scraper, rubber scraper, pitchfork, roller, etc.
Appropriate construction specifications
▷Primer : CLEANTHANE 1000
▷Intermediate coating : ECO-CLEANTHANE 2100, CLEANTHANE 2100 PLUS, CLEANTHANE 2100(KS), ENERGY SAVER Urethane(R) intermediate coating
▷Top coat : ENERGY SAVER Urethane(R) top coat
Coating conditions
1. Atmosphere Temperature: 5~35℃, Surface Temperature: 40℃ or below, Relative Humidity: 80% or less.