Heavy Duty Coating

DHDC-1650UL Inorganic ethyl silicate shop primer

usage
Temporary anti-corrosive primer for various steel pipes, tanks, and steel structures

This paint is a two-component inorganic zinc rich shop primer that is specially designed to be used under conditions where the surface treatment and painting process are automated because the drying speed is very fast. This paint is a fast-drying type, having very good adhesion and anti-corrosion properties. It is used as a shop primer for steel structures in shipyards and other extremely corrosive environments and can withstand temperatures of up to 400℃. In particular, cutting and electric welding workability is very excellent.

specification

Paint type
Zinc powder paste / Ethyl silicate
Drying time
Drying time
Category 5℃ 20℃ 30℃
Set-to-touch 5 minutes 3 minutes 1 minute
Dry-hard 20 minutes 10 minutes 5 minutes
Over-coat (Max.) 24 hours 16 hours 10 hours
Pot life 10 hours 8 hours 6 hours
Thinner
DR-660
Dilution ratio
▷Brush, roller coating: less than 5% ▷Airless, spray coating: less than 5%
Specific gravity
Approx. 1.4
Theoretical Coverage
14 ㎡/ℓ (1time - 20㎛)
Solid volume ratio
Approx. 28±1%
Color
Metal zinc gray
Thickness of dried film
20㎛
Mixing ratio
Base(A)/Hardener(B)=3/1 (Weight ratio)
Flash point
At least 11℃
Gloss
Matte
Shelf life
12 months (well-ventilated dry, cold and dark location)

PRODUCT PROPERTIES (PHYSICAL PROPERTY DATA)

Shop primer
A shop primer with a quick-drying speed, which can be used even in an automated painting process.
Excellent film property
Temporary anti-corrosive primer for steel structures, which is excellent in adhesion, anti-corrosive properties, heat resistance, and electric welding workability.

how to use

Surface treatment
1. Completely remove oil, moisture, sand, dust, and other foreign matter from the surface to be coated.
The degree of surface treatment to obtain an excellent steel protection effect should be at least SSPC-SP 10
or Sa2.5 (near white metal blast cleaning).
- Note that adhesion may be weak at a surface treatment grade of SSPC-SP 10 or less.
2. For steel, apply immediately after surface treatment.
3. If the subsequent paint is an inorganic zinc primer, the surface treatment should be sweep blasting or more
advanced process(SSPC-SP 7, NACE#4, Sa 1.0).
Coating method
1. Although coating can be done by either brush or airless spraying, airless spray coating is best.
2. Airless spray coating:
- Tip diameter : 0.013"~0.019"
- Injection pressure : More than 2500 P.S.I(176㎏/㎠)
- Store the coating equipment after cleaning with an exclusive thinner immediately after use.
3. Brush and roller coating should only be used on damaged parts of the coating and should not be repeated more than once.
Preceding and follow-up coating
1. Follow-up coating: Applicable to inorganic zinc system, 2K epoxy system, vinyl system, and chlorinated rubber system
2. Unsuitable follow-up coating: Oil-based top coats (ready mixed paint, air-drying enamel, etc.)
Remarks
1. Before use, thoroughly stir the main agent to make it uniform and use after slowly mixing the hardener and sufficiently stirring (After stirring, filter with a 30-60 mesh).
2. Continue stirring to avoid sedimentation during use. Excessive dilution is prohibited.
3. Due to the nature of the paint, self-re-coating is impossible. Please be sure to remove the coating if the coating is formed within the container during use.
4. Be careful to avoid contamination and damage to the coating by welding residue during welding work.