Heavy Duty Coating

DHDC-3650TL CLEAR Phenolic epoxy primer, clear

usage
Clear primer for concrete requiring a chemical-resistant atmosphere
Clear primer for heavy-duty concrete storage tanks

This paint is a phenolic epoxy clear paint that is applied to concrete to achieve excellent protection performance. It is excellent in adhesion and permeability and is the most suitable paint for the primer of concrete structures that require a chemical-resistant atmosphere such as water resistance, solvent resistance and alkali resistance.

specification

Paint type
Epoxy phenolic amine / Clear primer (Two-Component)
Drying time
Drying time
Category 5℃ 20℃ 30℃
Set-to-touch 4 hours 2 hours 1 hour
Dry-hard 24 hours 18 hours 12 hours
Over-coat (Min.) 32 hours 24 hours 16 hours
Over-coat (Max.) 15 days 7 days 5 days
Pot life 4 hours 3 hours 1 hour
Thinner
DR-100
Dilution ratio
▷Brush, roller coating: less than 15% ▷Airless, spray coating: less than 10%
Specific gravity
Approx. 1.1
Theoretical Coverage
11.2 ㎡/ℓ (1time - 90㎛)
Solid volume ratio
Approx. 90±1%
Color
Light yellow clear
Thickness of dried film
80㎛
Mixing ratio
Base(A)/Hardener(B)=2/1 (Volume ratio)
Flash point
At least 12℃
Gloss
Glossy
Shelf life
12 months (Dry, cool, and dark place with good ventilation)

PRODUCT PROPERTIES (PHYSICAL PROPERTY DATA)

Clear primer
A 2K phenolic epoxy clear primer for concrete with excellent chemical resistance
Excellent film property
Adhesion, permeability, solvent resistance and chemical resistance are excellent.

how to use

Surface treatment
1. Completely remove oil, moisture, sand, dust, and other foreign matter from the surface to be coated.
2. Sufficiently dry the surface to be coated before coating.
Coating method
1. Coating can be done by either brush, roller, air or airless spray coating.
2. Airless spray coating:
- Tip diameter : 0.021"~0.031"
- Injection pressure : More than 3000 P.S.I(210㎏/㎠)
- Store the coating equipment after cleaning with an exclusive thinner immediately after use.
Preceding and follow-up coating
1. Follow-up coating : Epoxy system(DHDC-3650TL) is suitable.
Remarks
1. Sufficient performance after last coating is achieved after drying for 7 days at 20℃.
2. For coating areas exposed to the outside, yellowing and chalking may occur in a short period of time due to
the effect of sunlight. Upon coating for areas exposed to the outside, be sure to apply top coat.