Heavy Duty Coating
DHDC-3650TL PRIMER Phenolic epoxy primer, high build
- usage
- Primer for steel structures under severe chemical environments
This paint is a premium epoxy phenolic amine primer that is used for the primer of structures in an environment that requires excellent adhesion to hard film and steel surfaces and a chemical-resistant atmosphere such as solvent resistance, and acid and alkali resistance. As it is a high build paint that can be applied at a thickness of up to 100㎛ in one coat, it can shorten the painting process.
specification
- Paint type
- Epoxy phenolic amine / Anti-corossive primer / High build (Two-Component)
- Drying time
-
Drying time Category 5℃ 20℃ 30℃ Set-to-touch 2 hours 1 hour 40 minutes Dry-hard 24 hours 18 hours 12 hours Over-coat (Min.) 32 hours 24 hours 16 hours Over-coat (Max.) 4 months 15 days 7 days Maturation time 30 minutes 20 minutes 10 minutes Pot life 5 hours 3 hours 2 hours - Thinner
- DR-100
- Dilution ratio
- ▷Brush, roller coating: less than 15% ▷Airless, spray coating: less than 10%
- Specific gravity
- Approx. 1.6
- Theoretical Coverage
- 7.2 ㎡/ℓ (1time - 100㎛)
- Solid volume ratio
- 약 72±1%
- Color
- Reddish brown
- Thickness of dried film
- 100㎛
- Mixing ratio
- Base(A)/Hardener(B)=5/1 (Weight ratio)
- Flash point
- At least 12℃
- Gloss
- Matte
- Shelf life
- 12 months (Dry, cool, and dark place with good ventilation)
PRODUCT PROPERTIES (PHYSICAL PROPERTY DATA)
- Primer for steel
- A 2K phenolic epoxy high-build primer for steel with superior chemical resistance
- Excellent film property
- Adhesion, anti-corrosive properties, solvent resistance and chemical resistance are excellent.
how to use
- Surface treatment
- 1. Completely remove oil, moisture, sand, dust, and other foreign matter from the surface to be coated.
The degree of surface treatment to obtain an excellent steel protection effect should be at least SSPC-SP 10
or Sa2.5 (near white metal blast cleaning).The surface roughness should not exceed 75 ㎛.
2. For steel, apply immediately after surface treatment.
3. After primer coating, clean up the welded areas (blackened and rusted areas) with a disc sander.
Then, touch up with this paint and continue coating. - Coating method
- 1. Although coating can be done by either brush or airless spraying, airless spray coating is best.
2. Airless spray coating:
- Tip diameter : 0.021"~0.031"
- Injection pressure : More than 3000 P.S.I(210㎏/㎠)
- Store the coating equipment after cleaning with an exclusive thinner immediately after use. - Preceding and follow-up coating
- 1. Follow-up coating : Epoxy system(DHDC-3650TL), urethane paint are suitable.
- Remarks
- 1. Sufficient performance after last coating is achieved after drying for 7 days at 20℃.
2. For coating areas exposed to the outside, yellowing and chalking may occur in a short period of time due to
the effect of sunlight. Upon coating for areas exposed to the outside, be sure to apply top coat.