Heavy Duty Coating
DHDC-3650TL Phenolic epoxy top coat, high build
- usage
- Top coat for various storage tanks, and structures in chemical environments (generally recommended for inside steel structures and tank linings)
This paint is a premium epoxy phenolic amine top coat that is used for the painting of structures in an environment that requires adhesion to hard film and a chemical-resistant atmosphere such as water resistance, solvent resistance, and acid and alkali resistance. It is especially suitable for the lining of various tanks for petroleum and solvents. As it is a high build paint that can be applied as the dry film at a thickness of up to 125㎛ in one coat, it can shorten the painting process.
specification
- Paint type
- Epoxy phenolic amine / Top coat / Thick film (2-Component)
- Drying time
-
Drying time Category 5℃ 20℃ 30℃ Set-to-touch 2 hours 1 hour 1 hour Dry-hard 24 hours 18 hours 12 hours Over-coat (Min.) 48 hours 24 hours 16 hours Over-coat (Max.) 1 month 15 days 7 days Maturation time 1 hour 30 minutes 20 minutes Pot life 5 hours 3 hours 2 hours - Thinner
- DR-100
- Dilution ratio
- ▷Brush, roller coating: less than 15% ▷Airless, spray coating: less than 10%
- Specific gravity
- Approx. 1.6
- Theoretical Coverage
- 7.2 ㎡/ℓ (1time - 125㎛)
- Solid volume ratio
- Approx. 90±1%
- Color
- Gray, other colors
- Thickness of dried film
- 125㎛
- Mixing ratio
- Base(A)/Hardener(B)=5/1 (Weight ratio)
- Flash point
- At least 12℃
- Gloss
- Glossy
- Shelf life
- 12 months (Dry, cool, and dark place with good ventilation)
PRODUCT PROPERTIES (PHYSICAL PROPERTY DATA)
- Chemical type
- 10% hydrochloric acid, 10% phosphoric acid, 50% sodium hydroxide, 50% methanol, Aircraft oil, gasoline, diesel
- Test method
- KS M ISO 2812-1
- Test result
- No problems
how to use
- Surface treatment
- 1. Completely remove oil, moisture, sand, dust, and other foreign matter from the surface to be coated.
2. Sufficiently dry the surface to be coated before coating.
3. The welded parts and corners need to be cleaned before coating. - Coating method
- 1. Although coating can be done by either brush or airless spraying, airless spray coating is best.
2. Airless spray coating:
- Tip diameter : 0.021"~0.031"
- Injection pressure : More than 3000 P.S.I(210㎏/㎠)
- Store the coating equipment after cleaning with an exclusive thinner immediately after use. - Preceding and follow-up coating
- 1. Preceding coating : steel - DHDC-3650TL PRIMER
concrete - DHDC-3650TL CLEAR - Remarks
- 1. Sufficient performance after last coating is achieved after drying for 7 days at 20℃.
2. For coating areas exposed to the outside, yellowing and chalking may occur in a short period of time
due to the effect of sunlight.