Heavy Duty Coating

DHDC-3650TL Phenolic epoxy top coat, high build

usage
Top coat for various storage tanks, and structures in chemical environments (generally recommended for inside steel structures and tank linings)

This paint is a premium epoxy phenolic amine top coat that is used for the painting of structures in an environment that requires adhesion to hard film and a chemical-resistant atmosphere such as water resistance, solvent resistance, and acid and alkali resistance. It is especially suitable for the lining of various tanks for petroleum and solvents. As it is a high build paint that can be applied as the dry film at a thickness of up to 125㎛ in one coat, it can shorten the painting process.

specification

Paint type
Epoxy phenolic amine / Top coat / Thick film (2-Component)
Drying time
Drying time
Category 5℃ 20℃ 30℃
Set-to-touch 2 hours 1 hour 1 hour
Dry-hard 24 hours 18 hours 12 hours
Over-coat (Min.) 48 hours 24 hours 16 hours
Over-coat (Max.) 1 month 15 days 7 days
Maturation time 1 hour 30 minutes 20 minutes
Pot life 5 hours 3 hours 2 hours
Thinner
DR-100
Dilution ratio
▷Brush, roller coating: less than 15% ▷Airless, spray coating: less than 10%
Specific gravity
Approx. 1.6
Theoretical Coverage
7.2 ㎡/ℓ (1time - 125㎛)
Solid volume ratio
Approx. 90±1%
Color
Gray, other colors
Thickness of dried film
125㎛
Mixing ratio
Base(A)/Hardener(B)=5/1 (Weight ratio)
Flash point
At least 12℃
Gloss
Glossy
Shelf life
12 months (Dry, cool, and dark place with good ventilation)

PRODUCT PROPERTIES (PHYSICAL PROPERTY DATA)

Chemical type
10% hydrochloric acid, 10% phosphoric acid, 50% sodium hydroxide, 50% methanol, Aircraft oil, gasoline, diesel
Test method
KS M ISO 2812-1
Test result
No problems

how to use

Surface treatment
1. Completely remove oil, moisture, sand, dust, and other foreign matter from the surface to be coated.
2. Sufficiently dry the surface to be coated before coating.
3. The welded parts and corners need to be cleaned before coating.
Coating method
1. Although coating can be done by either brush or airless spraying, airless spray coating is best.
2. Airless spray coating:
- Tip diameter : 0.021"~0.031"
- Injection pressure : More than 3000 P.S.I(210㎏/㎠)
- Store the coating equipment after cleaning with an exclusive thinner immediately after use.
Preceding and follow-up coating
1. Preceding coating : steel - DHDC-3650TL PRIMER
concrete - DHDC-3650TL CLEAR
Remarks
1. Sufficient performance after last coating is achieved after drying for 7 days at 20℃.
2. For coating areas exposed to the outside, yellowing and chalking may occur in a short period of time
due to the effect of sunlight.