Heavy Duty Coating
OREFLON-203 Fluoride resin contained top coat
- usage
- 1. Large structures: steel bridges and buildings, plants, etc.
2. Machinery: automobiles, aircrafts, vessels, home appliances, and other machines,
which require durability
3. Others: Steel structures exposed to direct sunlight for a long period of time
This paint is a super weather-resistant, room-temperature drying polyvinylidene fluoride paint with excellent chemical safety. As it shows strong performance in terms of weather resistance, chemical resistance (acid, alkali) and stain resistance, it is suitable for bridges of large steel structures, vessels and large factories. It is an excellent paint that is expanding its range of use as an advanced future paint from industrial use to heavy duty coating, taking advantage of its characteristics since the inception of the U.S. Apollo program.
specification
- Paint type
- Air-drying PVDF (Polyvinylidene Fluoride) / top coat (2-Component)
- Drying time
-
Drying time Category 5℃ 20℃ 30℃ Set-to-touch 2 hours 1 hour 40 minutes Dry-hard 20 hours 8 hours 6 hours Over-coat (Min.) 32 hours 12 hours 8 hours Over-coat (Max.) 10 days 7 days 5 days Maturation time 1 hour 30 minutes 20 minutes Pot life 8 hours 5 hours 3 hours - Thinner
- DR-4000, DR-4000(S)-summer time
- Dilution ratio (Volume)
- ▷Spray coating: less than 20% ▷Airless, spray coating: less than 15%
- Specific gravity
- Approx. 1.2(White)
- Theoretical Coverage
- 12.3 ㎡/ℓ (1 time - 30㎛)
- Solid volume ratio
- 37±1%
- Color
- White and ordered colors (Color limitation may apply due to paint properties.)
- Thickness of dried film
- 30㎛
- Mixing ratio
- Base(A)/Hardener(B)=7/1(Weight)
- Shelf life
- 12 months (Dry, cool, and dark place with good ventilation)
- Gloss
- Glossy, half-glossy and matte
PRODUCT PROPERTIES (PHYSICAL PROPERTY DATA)
- Weather resistance
- It is an air-drying paint boasting 20 years of weather resistance.
- Chemical resistance
- This paint is excellent in chemical resistance.
- Workability
- Repair painting is easy.
how to use
- Surface treatment
- 1. Completely remove oil, moisture, sand, dust, and other foreign matter from the surface to be coated.
2. Sufficiently dry the surface to be coated before coating.
3. The welded parts and corners need to be cleaned before coating. - Coating method
- 1. Coating can be done by either brush, roller, air or airless spray coating.
2. Airless spray coating :
- Tip diameter : 0.017"~0.021"
- Injection pressure : More than 2500 P.S.I (176㎏/㎠)
- Store the coating equipment after cleaning with an exclusive thinner immediately after use.
3. The surface to be coated must be clean. The surface temperature should be at least 3℃ higher than the dew point to avoid the condensation of water, and the relative humidity should be less than 85%. - Preceding and follow-up coating
- 1. Preceding coating : Epoxy system, urethane paint
- Remarks
- 1. Sufficient performance after last coating is achieved after drying for 7 days at 20℃.